A Comparative Analysis of the Piezoelectric Ultrasonic Appliance and Trephine Bur for Apical Location: An In Vitro Study

dc.contributor.authorCáceres Madroño, Esther
dc.contributor.authorRodríguez Torres, Paulina Andrea
dc.contributor.authorOussama, Soraya
dc.contributor.authorZubizarreta Macho, Álvaro
dc.contributor.authorBufalá Pérez, María
dc.contributor.authorMena Álvarez, Jesús
dc.contributor.authorRiad Deglow, Elena
dc.contributor.authorHernández Montero, Sofía
dc.date.accessioned2021-11-09T13:19:01Z
dc.date.available2021-11-09T13:19:01Z
dc.date.created2021-10-15
dc.description.abstractTo compare and contrast the accuracy of piezoelectric ultrasonic insert (PUI) and trephine bur (TB) osteotomy site preparation techniques for apical location. (1) Material and methods: A total of 138 osteotomy site preparations were randomly distributed into one of two study groups. Group A: TB technique (n = 69) and B: PUI technique (n = 69). A preoperative cone-beam computed tomography scan and an intraoral scan were performed and uploaded to implant-planning software to plan the virtual osteotomy site preparations for apical location. Subsequently, the osteotomy site preparations were performed in the experimental models with both osteotomy site preparation techniques and a postoperative CBCT scan was performed and uploaded into the implant-planning software and matched with the virtually planned osteotomy site preparations to measure the deviation angle and horizontal deviation as captured at the coronal entry point and apical end-point between osteotomy site preparations using Student¿s t-test statistical analysis. (2) Results: The paired t-test found statistically significant differences at the coronal entry-point deviations (p = 0.0104) and apical end-point deviations (p = 0.0104) between the TB and PUI study groups; however, no statistically significant differences were found in the angular deviations (p = 0.309) between the trephine bur and piezoelectric ultrasonic insert study groups. (3) Conclusions: The results showed that the TB is more accurate than the PUI for apical location.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.locationN/Aes_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12080/26159
dc.languageenges_ES
dc.rightsCC-BYes_ES
dc.rights.accessrightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.eses_ES
dc.subjectapical location; apicoectomy; cone-beam computed tomography scan; piezoelectric; trephine bures_ES
dc.titleA Comparative Analysis of the Piezoelectric Ultrasonic Appliance and Trephine Bur for Apical Location: An In Vitro Studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES