Novel Electronic Device to Quantify the Cyclic Fatigue Resistance of Endodontic Reciprocating Files after Using and Sterilization

dc.contributor.authorZubizarreta Macho, Álvaro
dc.contributor.authorAlonso Ezpeleta, Óscar
dc.contributor.authorAlbaladejo Martínez, Alberto
dc.contributor.authorFaus Matoses, Vicente
dc.contributor.authorCaviedes Brucheli, Javier
dc.contributor.authorAgustín Panadero, Rubén
dc.contributor.authorMena Álvarez, Jesús
dc.contributor.authorVizmanos Martínez-Berganza, Fernando
dc.date.accessioned2021-02-03T17:23:14Z
dc.date.available2021-02-03T17:23:14Z
dc.date.created2020-07
dc.description.abstractBackground: The aim of this study was to analyze the e ects of the time of use (TU) and sterilization cycles (SC) of endodontic reciprocating files on cyclic fatigue resistance. Methods: One-hundred-and-twenty (120) Procodile NiTi endodontic reciprocating instruments were selected at random and distributed into the following study groups: A: 0 sterilization cycles/0s time of use (n = 10); B: 0/60 (n = 10); C: 0/120 (n = 10); D: 1/0 (n = 10); E: 1/60 (n = 10); F: 1/120 (n = 10); G: 5/0 (n = 10); H: 5/60 (n = 10); I: 5/120 (n = 10); J: 10/0 (n = 10); K: 10/60 (n = 10); and L: 10/120 (n = 10). A dynamic cyclic fatigue device was designed using computer-aided design/computer-aided engineering (CAD/CAE) technology and created with a 3D printer to simulate the pecking motion performed by the clinician. Failure of the endodontic rotary instrument was detected by a light-emitting diode-light-dependent resistor (LED-LDR) system controlled by an Arduino driver complex and management software. The results were analyzed using the ANOVA test. Results: All pairwise comparisons presented statistically significant di erences between the time to failure, number of cycles to failure and number of cycles of in-and-out movement for the time of use study groups (p < 0.001), but not in the number of sterilization cycles (p > 0.05). Conclusions: The time of use of NiTi endodontic reciprocating files negatively a ects dynamic cyclic fatigue resistance. Dynamic cyclic resistance is not a ected by the number of sterilization cycles.es_ES
dc.formatapplication/pdfes_ES
dc.identifier.locationN/Aes_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12080/23948
dc.languageenges_ES
dc.rightsCC-BYes_ES
dc.rights.accessrightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.eses_ES
dc.titleNovel Electronic Device to Quantify the Cyclic Fatigue Resistance of Endodontic Reciprocating Files after Using and Sterilizationes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES

Files

Collections