Air particulate concentration during orthodontic procedures: a pilot study

dc.contributor.authorMartín Quintero, Inmaculada
dc.contributor.authorCervera Sabater, Alberto
dc.contributor.authorTapias Perero, Víctor
dc.contributor.authorNieto Sánchez, Iván
dc.contributor.authorde la Cruz Pérez, Javier
dc.date.accessioned2021-08-30T13:01:15Z
dc.date.available2021-08-30T13:01:15Z
dc.date.created2021
dc.description.abstractBackground: This study evaluates the particle dispersion involved in dental procedures carried out during orthodontic treatments. Variants such as temperature and relative humidity in the dental cabinet were considered. Methods: Using a particle counter, a pilot study was conducted, in which 98 consecutive recordings were made during appointments of patients undergoing orthodontic treatments. Temperature, relative humidity and particles present at the beginning (AR) and during the appointment (BR) were recorded. A control record (CR) of temperature, relative humidity and particles present was made before the start of the clinical activity. In addition to conventional statistics, differential descriptive procedures were used to analyse results, and the influence of relative humidity on particle concentration was analysed by statistical modelling with regression equations. Results: The number of particles present, regardless of their size, was much higher in AR than in CR (p < .001). The same was true for relative humidity and ambient temperature. The relationship between relative humidity and particle number was determined to be exponential. Limitations of the study: The limitations are associated with sample size, environmental conditions of the room and lack of discrimination among the procedures performed. Conclusions: This pilot study shows that from the moment a patient enters a dental office, a large number of additional particles are generated. During treatment, the number of particles of 0.3 microns¿which have a high capacity to penetrate the respiratory tract-increases. Moreover, a relationship between relative humidity and particle formation is observed. Further studies are needed. Keywords: Orthodontics, Dentistry, COVID-19, SARS-CoV-2, Bioaerosolses_ES
dc.formatapplication/pdfes_ES
dc.identifier.locationN/Aes_ES
dc.identifier.urihttps://hdl.handle.net/20.500.12080/25298
dc.languageenges_ES
dc.rightsCC-BYes_ES
dc.rights.accessrightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.eses_ES
dc.titleAir particulate concentration during orthodontic procedures: a pilot studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES

Files